7.6 SENSOR DISPLAY/ADJUSTMENT

7.6.1

Sensor Display/Adjustment Operation Example

< 1 > D I A G .
< 2 > P A R A M E T E R
< 3 > A D J U S T
< 4 > T E S T
< 5 > S E N S O R
[ H ] 2 0 ° C
[ S ] 4 0 ° C
[ R E F . < U > ]
[ R E F . < U > ]
Power OFF
[FEED] [PAUSE]
V 1 . 0 A
[FEED]
S E T
[FEED]
S E T
[FEED]
P R I N T
[FEED]
A D J .
[PAUSE]
[ A ] 2 2 ° C
[PAUSE]
[PAUSE]
2 . 8 V
[RESTART]
3 . 8 V *
[PAUSE]
(1) Power off state
(2) While
[PAUSE] keys, turn the power on.
(3) System mode menu display
(Self-test)
(4) Press the [FEED] key.
(5) System mode menu display
(Parameter setting)
(6) Press the [FEED] key.
(7) System mode menu display
(Fine adjustment value setting)
(8) Press the [FEED] key.
(9) System mode menu display
(Test print)
(10) Press the [FEED] key.
(11) System mode menu display
(Sensor display/adjustment)
(12) Press the [PAUSE] key.
(13) Thermal
adjustment value/open-air temperature
sensor adjustment value
(14) Press the [PAUSE] key.
(15) Heat sink sensor adjustment value
(16) Press the [PAUSE] key.
(17) Upper reflective sensor adjustment
value display:
Load tag paper.
should not be covered by the sensor.)
(18) Hold down the [RESTART] or [FEED]
key for 3 seconds or more.
(19) "*"
reflective
complete.
(20) Press the [PAUSE] key.