DC Power Service Check

The machine is partially operative, a motor turns, display is on or the Power On LED may
be on or off.
Step
Actions and Questions
1
Does the printer Beep 5 times and the Operator Panel
display all diamonds?
2
DC Power to Engine Board - Turn the power off and
disconnect the LVPS cable to J9 on the Engine Board. Turn
the power on and check the following voltages on the LVPS
cable.
* J9-1 +3.3 V dc
* J9-2 +5 V dc
* J9-3 +5 V dc
* J9-4 +24 V dc
* J9-5 +24 V dc
* J9-6 Ground
* J9-7 Ground
* J9-8 Ground
* J9-9 Ground
* J9-10 Ground
Note: All voltages are approximate values.
Are the voltages correct?
3
DC Voltages at RIP Board - Turn the power off and
disconnect the LVPS cable to J23 on the RIP Board. Turn
the Power Supply Assembly power on and check the
following voltages on the LVPS cable:
* J23-1 Ground
* J23-2 Ground
* J23-3 Ground
* J23-4 Ground
* J23-5 Ground
* J23-6 Ground
* J23-7 Ground
* J23-8 Ground
* J23-9
* J23-10 +3.3 V dc
* J23-11 +3.3 V dc
* J23-12 +3.3 V dc
* J23-13 +5.0 V dc
* J23-14 +5.0 V dc
* J23-15 +5.0 V dc
* J23-16 +24 V dc
Note: All voltages are approximate values.
Are the voltages correct?
2-54
Service Manual
5060-XXX
Yes
Go to the
"Operator
Panel LCD/
Status LED/
Buttons
Service
Check" on
page 2-81
Go to Step 3
Problem
Solved
No
Go to Step 2
Replace the
"LVPS" on
page 4-14
Replace the
"LVPS" on
page 4-14

Advertisement