Riso RP3700I User Manual page 184

Table of Contents

Advertisement

Advisory Messages
Message
Master Mis-Feed
Rewind Master Roll and
Reset Master in Place
Master Remains on Print Cylinder
(Drum)
Pull Out Print Cylinder (Drum) and
Remove Master
Master was Not Loaded
on Print Cylinder (Drum) Correctly
Pull Out Print Cylinder (Drum) and
Remove Master
Place Originals in ADF Again
Print Cylinder (Drum) has been
Unlocked
To Lock it Again, Pull it Out and
Set it Back in Place
!!System Error!!
Rewind Master Roll and
Close Scanner Table.
184
Description
Master has misfed.
A used master remains on
the Print Cylinder (Drum).
The master has not been
properly loaded on the Print
Cylinder (Drum).
The originals are not set
correctly in the ADF unit
(optional).
The Print Cylinder (Drum) is
ready to be pulled out.
The cutter did not operate in
master cutting.
Action
Open the Master Making Unit and wind
the master roll. Then reset master in
place. Press the Start key to resume
operation.
p.167... Replacing the Master Roll
q Open the Front Cover and pull out
the Print Cylinder (Drum). Then
remove the master on the Print
Cylinder (Drum) and return the
cylinder (drum) into the original
position.
w Open the Master Making Unit and
wind the master roll. Then reset
master in place. After closing the
Master Making Unit, resume
operation from master-making.
p.171... Changing Print Cylinders
(Drums)
p.167... Replacing the Master Roll
q Open the Front Cover and pull out
the Print Cylinder (Drum). Then
remove the master on the Print
Cylinder (Drum) and return the
cylinder (drum) into the original
position.
w Open the Master Making Unit and
wind the master roll. Then reset
master in place. After closing the
Master Making Unit, resume
operation from master-making.
p.171... Changing Print Cylinders
(Drums)
p.167... Replacing the Master Roll
Make sure that the original is face-
down, and then insert it into the ADF
Unit until it stops.
p.28... Basic Procedure
Pull out the Print Cylinder (Drum) and
then reset it in place.
p.171... Changing Print Cylinders
(Drums)
Open the Scanner Table and the
Master Making Unit. Once remove the
master roll and close the Master
Making Unit and the Scanner Table,
then open them again and reset the
master correctly.
p.167... Replacing the Master Roll

Hide quick links: