Port Mirroring Configuration; Port Mirroring Overview - Zte ZXR10 5900 Series User Manual

All gigabit-port intelligent routing switch
Hide thumbs Also See for ZXR10 5900 Series:
Table of Contents

Advertisement

FE electrical port and GE electrical port are both connected to other
devices with a network cable. There are four twisted pairs in a
network cable. There are four twisted pairs in a network cable.
The FE electrical port uses pairs 1-2 and 3-6, and the GE electrical
port uses all four pairs (1-2, 3-6, 4-5 and 7-8). Line detection is
to test the state of each twisted pair, which includes:
1. Open: open line
2. Short: short circuit
3. Good: normal line
4. Broken: open/broken line
5. Unknown: unknown line or no result
6. Crosstalk line coupling
7. Fail: detection failure
In case of line fault, the location of failure is output. If the line is
normal, the approximate length of the line is output. To diagnose
and analyze a line, run the show vct interface command in any
configuration modes other than user configuration mode.
Example: Detect the line of port gei_1/2.
ZXR10(config)#show vct int gei_1/2
CableStatus
Good
Pair
1-2
Status
Good
Length
<50m
Caution:
Line diagnosis and analysis will restart the tested port, when links
of the port is broken and then restored. This function is used only
for faulty ports, and is not recommended for ports connected to
users.

Port Mirroring Configuration

Port Mirroring Overview

Port mirroring is to copy data from one or more ports (mirrored
ports) of a switch to a specified destination port (monitor port).
This data is obtained from the mirrored port(s). It provides an
effective tool for the maintenance and monitoring of the switch.
Also it supports cross-equipment port mirroring (RSPAN).
Port mirroring function of ZXR10 5900/5200 complies with the fol-
lowing rules:
Support up to one group of ports (eight mirrored ports to the
most).
Support cross-board port mirroring, that is, the mirrored port
and monitor port can be on different interface boards.
Confidential and Proprietary Information of ZTE CORPORATION
Chapter 4 Interface Configuration
3-6
4-5
7-8
Good
Good
Good
<50m
<50m
<50m
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents