Zte ZXR10 5900 Series User Manual page 49

All gigabit-port intelligent routing switch
Hide thumbs Also See for ZXR10 5900 Series:
Table of Contents

Advertisement

Command
show interface brief
ZXR10#
Example
The output of the viewing interface running status command is as
follows.
ZXR10#show interface brief
Interface
portattribute
gei_2/1
electric
gei_2/2
electric
gei_2/3
electric
gei_2/4
electric
gei_2/5
electric
gei_2/6
electric
gei_2/7
electric
gei_2/8
electric
Admin, Phy, and Prot indicate management, physical, and protocol
status of interface respectively. Only all three states are up, is
interface in normal working status.
At the interface configuration mode, input shutdown , the Admin
state of the interface will turn down.
lists some abnormal interface conditions and handling procedures.
T
4 I
S
ABLE
NTERFACE
TATE
Interface State
Admin is DOWN
Phy is UP
Prot is DOWN
Admin is UP
Phy is DOWN
Prot is DOWN
Admin is UP
Phy is UP
Prot is DOWN
Confidential and Proprietary Information of ZTE CORPORATION
Chapter 4 Interface Configuration
Function
This views interface running
status.
mode
BW(Mbits) Admin Phy
Duplex/full
1000
Duplex/full
1000
Duplex/full
1000
Duplex/full
1000
Duplex/full
1000
Duplex/full
1000
Duplex/full
1000
Duplex/full
1000
A
C
BNORMAL
ONDITION
Analysis and Solution
This indicates that physical
connection is normal and the
corresponding interface maybe
is shutdown, carry out the no
shutdown command at the
interface mode.
This indicates that physical link
has problem, check physical link.
Check interface configuration , the
problem maybe is that interface
parameter is not correct or is not
configured. refer to user manual
to solve the problem. if this
problem can't be solved contact
ZTE client supporting engineer for
further handling.
Prot Description
up
up
up
none
up
up
up
none
up
up
up
none
up
up
up
none
up
up
up
none
up
up
up
none
up
down
down
none
up
down
down
none
35