3Com 4210 PWR Configuration Manual page 367

9/18/26 port and pwr 9/18/26 port 4210 series switch
Table of Contents

Advertisement

[4210-Ethernet1/0/1] rmon statistics 1
[4210-Ethernet1/0/1] quit
# Add the event entries numbered 1 and 2 to the event table, which will be trigg
ered by the following extended alarm.
[4210] rmon event 1 log
[4210] rmon event 2 trap 10.21.30.55
# Add an entry numbered 2 to the extended alarm table to allow the system to
calculate the alarm variables with the
(.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1) formula to get the numbers
of all the oversize and undersize packets received by Ethernet 1/0/1 that are in
correct data format and sample it in every 10 seconds. When the change ratio
between samples reaches the rising threshold of 50, event 1 is triggered; when the
change ratio drops under the falling threshold, event 2 is triggered.
[4210] rmon prialarm 2 (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1)
test 10 changeratio rising_threshold 50 1 falling_threshold 5 2 entrytype fo
rever owner user1
# Display the RMON extended alarm entry numbered 2.
[4210] display rmon prialarm 2
Prialarm table 2 owned by user1 is VALID.
Samples type
Variable formula : (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1)
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever.
Latest value
RMON Configuration Examples
: changeratio
: test
: 10(sec)
: 100(linked with event 1)
: 10(linked with event 2)
: risingOrFallingAlarm
: 0
365