3Com 4210 PWR Configuration Manual page 296

9/18/26 port and pwr 9/18/26 port 4210 series switch
Table of Contents

Advertisement

294
C
27: ACL C
HAPTER
Configuring Basic ACL
ONFIGURATION
Note that:
If only a periodic time section is defined in a time range, the time range is
active only when the system time is within the defined periodic time section. If
multiple periodic time sections are defined in a time range, the time range is
active only when the system time is within one of the periodic time sections.
If only an absolute time section is defined in a time range, the time range is
active only when the system time is within the defined absolute time section. If
multiple absolute time sections are defined in a time range, the time range is
active only when the system time is within one of the absolute time sections.
If both a periodic time section and an absolute time section are defined in a
time range, the time range is active only when the periodic time range and the
absolute time range are both matched. Assume that a time range contains an
absolute time section ranging from 00:00 January 1, 2004 to 23:59 December
31, 2004, and a periodic time section ranging from 12:00 to 14:00 on every
Wednesday. This time range is active only when the system time is within the
range from 12:00 to 14:00 on every Wednesday in 2004.
If the start time is not specified, the time section starts from 1970/1/1 00:00
and ends on the specified end date. If the end date is not specified, the time
section starts from the specified start date to 2100/12/31 23:59.
Configuration Example
# Define a periodic time range that spans from 8:00 to 18:00 on Monday through
Friday.
<4210> system-view
[4210] time-range test 8:00 to 18:00 working-day
[4210] display time-range test
Current time is 13:27:32 Apr/16/2005 Saturday
Time-range : test ( Inactive )
08:00 to 18:00 working-day
# Define an absolute time range spans from 15:00 1/28/2006 to 15:00 1/28/2008.
<4210> system-view
[4210] time-range test from 15:00 1/28/2006 to 15:00 1/28/2008
[4210] display time-range test
Current time is 13:30:32 Apr/16/2005 Saturday
Time-range : test ( Inactive )
From 15:00 Jan/28/2000 to 15:00 Jan/28/2004
A basic ACL filters packets based on their source IP addresses.
A basic ACL can be numbered from 2000 to 2999.
Configuration Prerequisites
To configure a time range-based basic ACL rule, you need to create the
corresponding time range first. For information about configuring the time ,
refer to "Configuring a Time Range" on page 293.