Handlebar Control Switches - Arctic Cat 350 2011 Service Manual

Table of Contents

Advertisement

For Discount Arctic Cat Parts Call 606-678-9623 or 606-561-4983
VOLTAGE
 NOTE: Perform this test on the main harness connector.
1. Set the meter selector to the DC Voltage position.
2. Connect the red meter lead to the red/white wire;
then connect the black meter lead to ground.
3. Meter must show battery voltage.
 NOTE: If the meter shows no battery voltage, trou-
bleshoot the battery or the main wiring harness.
RESISTANCE
 NOTE: Perform this test on the switch harness
using the following procedure.
1. Turn the ignition switch to the ON position.
2. Set the meter selector to the OHMS position.
3. Connect either tester lead to pin B; then connect the
other tester lead to pin A.
4. The meter must show less than 1 ohm.
5. Turn the ignition switch to the LIGHTS position.
The meter must show less than 1 ohm.
6. Leaving the tester lead on pin B, connect the other
tester lead to pin C.
7. The meter must show less than 1 ohm.
 NOTE: If the meter shows more than 1 ohm of resis-
tance, replace the switch.
5-8
KC339D
KC276A
www.mymowerparts.com
Manual
Table of Contents
Handlebar Control
Switches
The connectors are located on the right side of the ATV
next to the PDM. To access the connector, the electrical
cover must be removed.
 NOTE: These tests should be made on the switch
side of the connector.
RESISTANCE (HI Beam)
1. Set the meter selector to the OHMS position.
2. Connect one tester lead to the brown/black wire; then
connect the other tester lead to the lavender wire.
3. With the dimmer switch in the HI position, the meter
must show less than 1 ohm.
 NOTE: If the meter shows more than 1 ohm of resis-
tance, replace the switch.
RESISTANCE (LO Beam)
1. Connect one tester lead to the brown/black wire; then
connect the other tester lead to the white wire.
2. With the dimmer switch in the LO position, the
meter must show an open circuit.
 NOTE: If the meter reads resistance, replace the switch.
RESISTANCE (Emergency Stop)
1. Set the meter selector to the OHMS position.
2. Connect the one lead to the brown/lavender wire;
then connect the other tester lead to the black/white
wire.
3. With the switch in the OFF position, the meter must
show an open circuit.
4. With the switch in the RUN position, the meter must
show less than 1 ohm.
 NOTE: If the meter shows more than 1 ohm of resis-
tance, replace the switch.
RESISTANCE (Reverse Override)
1. Set the meter selector to the OHMS position.
2. Connect one tester lead to one lavender/red wire;
then connect the other tester wire to the green/red
wire. The meter must show less than 1 ohm.
3. Depress and hold the reverse override button. The
meter must show an open circuit.
 NOTE: If the meter does not show as specified,
replace the switch.
Section
Table of Contents

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

425 2011

Table of Contents