22
sfpShow
To display detailed information about all SFPs:
912
switch:user> sfpshow -all
(output trunctaed)
=============
Slot
2/Port 14:
=============
Port 30 does not use an SFP!
=============
Slot
2/Port 15:
=============
Port 31 does not use an SFP!
=============
Slot
3/Port
0:
=============
Identifier:
3
SFP
Connector:
7
LC
Transceiver: 700c406000000000 4,8,16_Gbps \
M5,M6 sw Inter,Short_dist
Encoding:
6
64B66B
Baud Rate:
140
(units 100 megabaud)
Length 9u:
0
(units km)
Length 9u:
0
(units 100 meters)
Length 50u:
4
(units 10 meters)
Length 62.5u:2
(units 10 meters)
Length Cu:
0
(units 1 meter)
Vendor Name: BROCADE
Vendor OUI:
00:05:1e
Vendor PN:
57-0000088-01
Vendor Rev:
A
Wavelength:
850
(units nm)
Options:
003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max:
0
BR Min:
0
Serial No:
HAA110491000HJ2
Date Code:
101208
DD Type:
0x68
Enh Options: 0xfa
Status/Ctrl: 0xb2
Pwr On Time: 0.17 years (1498 hours)
Alarm flags[0,1] = 0x0, 0x40
Warn Flags[0,1] = 0x0, 0x40
Temperature:31
Centigrade -5
Current: 0.002
mAmps
Voltage: 3260.9
mVolts
RX Power:-16.4 dBm (22.8 uW) 31.5 uW 2000.0 uW 31.5
TX Power:-40.0 dBm (0.1
State transitions: 1
(output truncated)
Alarm
low
high
low
85
0
2.500
10.500
2.500
3000.0 3600.0
3130.0
uW)126.0 uW 2000.0 uW 317.0 uW 790.0 uW
Warn
high
80
10.500
3460.0
uW 790.0 uW
Fabric OS Command Reference
53-1001764-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents