Saved Data Call Command ([Esc] Xq) - Toshiba B-SX4T Series Specification

B-sx4t series, b-sx5t series external equipment interface specification
Hide thumbs Also See for B-SX4T Series:
Table of Contents

Advertisement

6.3.28 SAVED DATA CALL COMMAND (For Flash Memory)
Function
Calls PC interface commands saved in flash memory.
Format
[ESC] XQ; aa, (Sb,) c, d [LF] [NUL]
Term
aa:
Sb:
c:
d:
Notes
(1)
(2)
(3)
(4)
Refer to
• Save Start Command ([ESC] XO)
• Save Terminate Command ([ESC] XP)
Examples
[ESC] XQ; 01, 0, L [LF] [NUL]
[ESC] RC001; Sample [LF] [NUL]
[ESC] RC002; 100 [LF] [NUL]
[ESC] XS; I, 0002, 0002C3000 [LF] [NUL]
Identification number of the file to be called from the flash memory card
01 to 99
Drive from which the command is called
(Omissible. If omitted, flash ROM on the CPU board is selected.)
b: Drive
0: Flash ROM on the CPU board
1: Slot 1 on the PCMCIA board (Option)
2: Slot 2 on the PCMCIA board (Option)
Status response when the data is called up
0: No status response made
1: Status response made
Auto call at power on time
L:
Auto call
M: No auto call
If the relevant save identification number is not found, an error will result.
However, if no save identification number subject to auto call is found with the
option for auto call at power on time selected, the option for no auto call will be
selected causing no error.
If a command error is found in the PC interface command in auto call at power on
time by the Saved Data Call Command, a command error will result. After an
error has occurred, the power must be turned off. The option for no auto call is
selected when the power is turned on again.
The printer enters the online mode (label issue operation) when the Save Data
Call Command is sent after the Save Terminate Command.
- 221 -