In the case of GS1 DataBar
Format
[ESC] XBaa; bbbb, cccc, d, e, ff, g, hhhh (, ijjjjjjjjjj, kk) (, Sll) (= sss ------ sss) [LF]
[NUL]
[ESC] XBaa; bbbb, cccc, d, e, ff, g, hhhh (, ijjjjjjjjjj, kk) (, Sll) (; tt
[LF] [NUL]
Term
aa:
bbbb:
cccc:
d:
e:
ff:
g:
hhhh:
ijjjjjjjjjj:
jjjjjjjjjj: Skip value
kk:
ll:
Bar code number
00 to 31
Print origin of X-coordinate of the bar code
Fixed as 4 digits (in 0.1 mm units)
Print origin of Y-coordinate of the bar code
4 or 5 digits (in 0.1 mm units)
Type of bar code
b:
GS1 DataBar family
Version (Type of GS1 DataBar)
1:
GS1 DataBar Omnidirectional/GS1 DataBar Truncated
2:
GS1 DataBar Stacked
3:
GS1 DataBar Stacked Omnidirectional
4:
GS1 DataBar Limited
5:
GS1 DataBar Expanded
6:
GS1 DataBar Expanded Stacked
1-module width
01 to 15 (in dots)
Rotational angle of bar code
0: 0°
1: 90°
2: 180°
3: 270°
Height of the bar code
0000 to 1000 (in 0.1 mm units)
In the case of GS1 DataBar Truncated, set a value obtained by multiplying
one module width by 13.
Increment/decrement
(Omissible. If omitted, incrementing/decrementing is not performed.)
i: Indicates whether to increment or decrement
+: Increment
-: Decrement
0000000000 to 9999999999
No. of zeros to be suppressed
(Omissible. If omitted, the zero suppression process is not performed.)
00 to 20
Segment width (Omissible. When omitted, "04" is specified.)
02 to 22 (Even number only. Specifying an odd number causes a
command error.)
This parameter is effective only for GS1 DataBar Expanded Stacked.
(Version (type of GS1 DataBar): 6)
Setting this parameter to "22" makes the symbol look similar to the GS1
DataBar Expanded.
- 99 -
, tt
, tt
, ------, tt
)
1
2
3
20