(3)
More than one Bar Code Format Command can be connected when transmitted.
[ESC]
XB01; 0100, 0150, 3, 1, 02, 02, 06, 06, 02, 0, 0150 [LF]
B02; 0350, 0150, 3, 1, 02, 02, 06, 06, 02, 0, 0150 [LF] [NUL]
(4)
When the drawing data is changed per label issue during printing, the field of the drawing
data for the previous label is automatically cleared using the bar code number, then the next
drawing data is printed. Therefore, the bar code number which differs according to the
drawing fields should be designated.
between the Clear Command ([ESC] C) and Issue Command ([ESC] XS), the fixed data
may be drawn using the same bar code number. In this case, the Format Command and
Data Command should be sent alternately. (After the Issue Command is sent, the fields
with the same bar code number are automatically cleared until the Clear Command is sent.)
(5)
The link field designation is cleared by omitting the link field designation using the same bar
code No. and reformatting data.
The link field designation can also be cleared by the Image Buffer Clear Command.
(6)
A print data string and the link field No. cannot be programmed at the same time.
Refer to
Bit Map Font Format Command ([ESC] PC)
Outline Font Format Command ([ESC] PV)
Bar Code Data Command ([ESC] RB)
Since the automatic field clear is not performed
- 139 -