Download  Print this page

Toshiba B-SX4T Series Specification Page 364

B-sx4t series, b-sx5t series external equipment interface specification.
Hide thumbs

Advertisement

Type of Bar Code: MSI
(1) No affix
No. of Input Digits
Input
Data
Max. 15 digits
Drawing
Data
16 digits or more
(2) IBM modulus 10 check
No. of Input Digits
Input
Min. 2 digits
Data
Max. 15 digits
(including C/D)
Drawing
Data
1 digit
16 digits or more
(3) Auto affix of IBM modulus 10
No. of Input Digits
Input
Data
Max. 14 digits
Drawing
Data
15 digits or more
(4) IBM modulus 10 + Auto affix of IBM modulus 10
No. of Input Digits
Input
Data
Max. 13 digits
Drawing
Data
14 digits or more
(5) IBM modulus 11 + Auto affix of IBM modulus 10
No. of Input Digits
Input
Data
Max. 13 digits
Drawing
Data
14 digits or more
D
D
D
D
D
1
2
3
4
5
D
D
D
D
D
1
2
3
4
5
Not to be drawn
D
D
D
D
D
1
2
3
4
5
D
D
D
D
D
1
2
3
4
5
Not to be drawn
D
D
D
D
D
1
2
3
4
5
D
D
D
D
D
1
2
3
4
5
Not to be drawn
D
D
D
D
D
1
2
3
4
5
D
D
D
D
D
1
2
3
4
5
Not to be drawn
D
D
D
D
D
1
2
3
4
5
D
D
D
D
D
1
2
3
4
5
Not to be drawn
- 384 -
D
D
D
D
6
7
8
9
Not recognized as a check digit.
D
D
D
D
6
7
8
9
D
D
D
D
D
6
7
8
9
10
To be checked as IBM modulus 10
D
D
D
D
D
6
7
8
9
10
D
D
D
D
6
7
8
9
D
D
D
D
C/D
6
7
6
9
D
D
D
D
6
7
8
9
D
D
D
D
C/D
C/D
6
7
6
9
1
D
D
D
D
6
7
8
9
D
D
D
D
C/D
C/D
6
7
6
9
1
Affix IBM modulus 10.
2
Affix IBM modulus 10.
Affix IBM modulus 10.
2
Affix IBM modulus 10.
Affix IBM modulus 11.