Setting the Error Log Collection Level
The error log (the HDLM manager log (dlmmgrn.log (n indicates a file
number from 1 to 16)) collection level can be set.
Table 3-58 Values for the Error Log Collection Level Setting on page 3-188
lists and describes the values for the error log collection level setting.
0
1
2
3
4
If an error occurs, you might have to change the collection level to 1 or
higher to collect any log information.
The higher this value is set, the more information that will be output. As the
amount of log information to be output increases, it will take less time to
overwrite the old error log information with the new information.
The following is an example of using a command to set the error log
collection level.
# /opt/DynamicLinkManager/bin/dlnkmgr set -ellv 2
Specify the error log collection level as a number.
Setting the Trace Level
You can set up the trace level for a trace file hdlmtrn.log (n indicates a file
number from 1 to 64).
Table 3-59 Values for the Trace Level Setting on page 3-188
describes the possible values for the trace level setting.
0
1
2
3
3-188
Table 3-58 Values for the Error Log Collection Level Setting
Value
No error logs are collected.
All information for errors of the "Error" level or higher is collected.
All information for errors of the "Warning" level or higher is
collected.
All information for errors of the "Information" level or higher is
collected.
All information for errors of the "Information" level or higher
(including maintenance information) is collected.
Table 3-59 Values for the Trace Level Setting
Value
No trace is output.
Only error information is output.
Program operation summaries are output.
Program operation details are output.
Creating an HDLM Environment
Hitachi Dynamic Link Manager User Guide (for Linux(R))
Description
lists and
Description