Hitachi XP P9500 User Manual page 440

Command suite for linux(r)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

all the specified HDLM devices (/dev/sddlmaa, /dev/sddlmab, and /dev/
sddlmac) is executed continuously.
After changing partition configuration directly from a SCSI device for LUs
corresponding to the HDLM devices not to be managed, if the HDLM
device is returned to management target, execute the following
operations:
a
.
b
.
If you execute the dlmcfgmgr utility with the -i parameter specified, the
HDLM device that is not a management target can be changed to a
managed status. At this time, if an error occurs anywhere on the paths to
an HDLM device and you change that HDLM device to a managed status,
the message KAPL08026-E might be output to the syslog. However, HDLM
operations are not affected.
If you execute the dlmcfgmgr utility with the -r parameter specified, the
I/O and I/O error counts for existing paths displayed when the HDLM
command (dlnkmgr view -path) is executed are initialized to 0.
If you execute the dlmcfgmgr utility with the -r parameter specified while
one or more HDLM devices are mounted, an error message (KAPL05023-
E) is output to the syslog. However, HDLM operations are not affected.
If an HDLM device that is managed on the active host is changed to be
managed on the standby node, and then the same HDLM device is
excluded from management on the standby node then, during the cluster
creation, an error will occur when the active node is failed over. When the
dlmcfgmgr utility is executed with the -o parameter specified to exclude
an HDLM device from management on the standby node, make sure that
you exclude the same HDLM device from management on the active
node.
When an HDLM device is bound to a raw device, do not attempt to
exclude that HDLM device from management by executing the dlmcfgmgr
utility with the -o parameter specified. If the HDLM device is not being
managed, an error will occur when the raw device is accessed.
After configuring an HDLM device by executing the dlmcfgmgr utility, do
not change the settings of the sysfs interface that handles SCSI devices.
After configuring an HDLM device by executing the dlmcfgmgr utility, if
you unload the HBA driver, perform the following operations. If you load
the HBA driver without first performing the operations, the number of
HDLM paths that cannot be used might increase.
a
.
b
.
If you execute the dlmcfgmgr utility with the -r parameter after
dynamically deleting an SCSI device, the HDLM device will become
unavailable. If you then add the SCSI device dynamically and execute the
7-30
Execute the dlmcfgmgr utility with the -i parameter specified.
Execute the dlmcfgmgr utility with -r parameter specified.
Update the HDLM device with information about unavailable SCSI
devices by executing the dlmcfgmgr utility with the -r parameter
specified.
Delete the HDLM device by executing the dlmcfgmgr utility with all
specified in the -u parameter.
Utility Reference
Hitachi Dynamic Link Manager User Guide (for Linux(R))

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Dynamic link manager

Table of Contents