Manager host IP
The IP Gateway sends, without the need for registration, SNMP Trap_PDUs to the SSC
manager with "Manager host IP" address.
Manager Port ID
The IP Gateway sends SNMP Trap_PDUs to the SSC manager with non-standard SNMP Port
ID.
MIB II
The following four fields are part of MIB II parameters that define the contact person's name
and the location of the Gateway, as well as the Community Strings that serve as passwords for
accessing the Gateway.
Contact
The name of the contact person responsible for setting, configuring and maintaining the IP
Gateway and all NFM RTUs and devices installed at the communication sites.
Location
For maintenance purposes, the address of the location of the IP Gateway device should be
provided. The NMC application or the MIB Browser can retrieve this address by using the IP
Gateway MIB.
Community Read
The definition of the Community String Read provides a READ security password to the IP
Gateway. The NMC should supply the same Community String (case sensitive) in order to
read information from the IP Gateway: (Get_PDU/Get_Next_PDU Requests PDUs) and for
sending Traps.
Community Write
The definition of the Community String Write provides a WRITE security password to the IP
Gateway. The NMC should supply the same Community String (case sensitive) in order to
write information to the IP Gateway: Set_PDU Request.
DB refresh interval[s]
The database refresh interval specifies the refresh (validity) interval in seconds of the data
received from the sites in the internal IP Gateway cache. The data is discarded after this
interval expires.

Icons

Icon
Corresponding menu command
File menu, New command
File menu, Open command
File menu, Save command
File menu, Download command
File menu, Upload command