Motorola MOSCAD 68P02958C00-B User Manual page 367

Toolbox version 5.50
Table of Contents

Advertisement

8. The minimum waiting time (in msec) between one frame transmission and the next. It is measured
from the end of the constant tone of the last transmission.
9. To detect a busy channel:
Channel Monitor - The channel is busy when C.M. is active.
Tone Detect - The channel is busy when there is tone on the channel.
10. The amount of quiet time on the radio (msec).
11. The amount of busy time on the radio, meaning Radio Tone Detect is active.
## 1502
LEVEL = 2
Trunk Radio Configuration parameters :
Is trunk radio configured ?
No trunk-channel time before requesting TxEn
No trunk-channel time before requesting TxEn
Quiet Trunk-channel time before requesting TxEn
TxEn-request PTT active time mS
TxEn-request PTT non-active time mS
Wait for trunk-channel-access timeout Sec
Warmup trunk-channel time mS
Transmission timeout Sec
Wait for holdup timeout Sec
Trunk-channel holdup time mS
Trunk-channel shutup time mS
Current status of trunk :
Trunk-channel quiet time mS
Trunk-channel busy time mS
Channel does not exist time mS
Is txen active ?
Is PTT pressed and txen requested ?
Time remaining for PTT pressing or reset mS
1. YES - Trunk has been defined in configuration. Radio transmissions are via trunk.
NO - Trunk not used (regular radio transmission).
2. When the channel does not exist, this parameter determines the allotted time (in msec), to ask for
TxEn (transmit enable). This parameter is relevant if one of the functions, TxWdth or TxIntr was
called with Tx_Lnk=1 (Tx_Lnk=LoTrnk or Radio).
3. When the channel does not exist, this parameter determines the allotted time (in msec), to ask for
TxEn (transmit enable). This parameter is relevant if one of the functions, TxIntr or TxWdth was
called with Tx_Lnk=11.
4. When the channel exists and is quiet, this parameter determines the time (in msec) until asking for
TxEn (transmit enable). This parameter is relevant if one of the functions, TxWdth or TxIntr has
been called with Tx_Lnk=11 (Tx_Lnk=HiTrnk).
5. These two parameters, are used to determine the PTT active time (pressed) and PTT release time
after the transmit enable TxEn request (both in msec).
6. Maximum waiting time (in msec) for available channel for transmission. If at the end of this period,
the channel is not available, the system provides a failure notice and the transmission attempts will
be terminated.
(Low)
(High)
(High) : %% 4
C-75
Software Diagnostics Output
: %% 1
: %% 2
: %% 3
: %% 5
: %% 5
: %% 6
: %% 7
: %% 8
: %% 9
: %% 10
: %% 11
: %% 12
: %% 13
: %% 14
: %% 15
: %% 16
: %% 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Moscad

Table of Contents