Points To Note When Handling The Primary Grid Plate And The Primary Charging Wire; Developing Assembly-Related Parts; Replacing The Developer - Canon CLC5000 Service Manual

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
2.4.2 Points to Note When Handling the Primary Grid Plate and the Primary
Charging Wire
Do not clean the primary grid plate or the
primary charging wire. If image faults (un-
even density) occurs, replace the part.

2.5 Developing Assembly-Related Parts

2.5.1 Replacing the Developer

1) Insert the door switch actuator into the
door switch assembly.
2) Turn on the power, and insert and turn
the control key.
3) Start service mode, and select 'FUNC
IN-STALL'.
4) Select the 2nd screen, and set 'LSNS-
KIL' to '1'.
5) Select '0' by executing 'ADJSUT
PASCAL
PASCAL'.
6) Wait until warm-up ends.
7) Lift the hopper assembly to the topmost
position. (At this time, the locking
mechanism will turn on automatically.
Make a visual check of the hopper as-
sembly to make sure that the hopper as-
sembly is locked.)
8) Install the hopper retaining fixings (left,
right).
9) Release the hopper assembly, and move
the assembly down to where the retain-
ing fixings are located.
5-24
COPYRIGHT © 2001 CANON INC.
Hopper assembly
Hopper retaining
fixing
F05-205-01
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
Lock

Advertisement