CHAPTER 2 NEW FUNCTIONS
6) Turn the cam [9] by hand so that the
belt unit [10] is in UP position.
7) Disconnect the two connectors [11], and
loosen the screw [12]; then, shift the
lock plate [13] to the left.
8) Push the cleaning blade [14] with your
finger to release the pressure; then, lift
the inlet guide [15] while supporting it
at its center.
When lifting the inlet guide, be
sure to support it at its center;
otherwise, the guide plate can
deform.
2-70
COPYRIGHT © 2001 CANON INC.
[10]
F02-405-46
[11]
[12]
F02-405-47
F02-405-48
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
[9]
[13]
[15]
[14]