CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
2.7 When Replacing the Pick-Up/Feeding-Related Parts
2.7.1 Registering the Cassette/Multifeeder Paper Width Basic Setting
(under 'FUNC')
You must register the paper width basic
setting if you have
•
Replaced the paper width VR of the
copier (including the multifeeder).
•
Adjusted the front/rear registration
for the cassette.
For the cassette, you must register the set-
ting for 'STMTR' and 'A4R'; for the
multifeeder, you must register the setting
for 'A6R', 'A4R', and 'A4'.
a. Cassette 1 or 2
1) Slide out the cassette you want to regis-
ter the setting for, and set the paper
width guide plate inside the cassette to
A4R.
2) Set the cassette in the copier.
3) Check that the basic setting is indicated
on the CST-AD screen of 'FUNC' in
service mode on the control panel.
4) Select the size of the cassette for which
you want to register the basic setting:
UP-A4R (cassette 1)
LOW-A4R (cassette 2)
5) Note that basic setting 1 has been regis-
tered.
6) Slide out the cassette you want to regis-
ter the setting for, and set the paper
width guide plate inside the cassette to
STMTR.
7) Set the cassette in the copier.
8) Check that the basic setting is indicated
on the CST-AD screen of 'FUNC' in
service mode on the control panel.
9) Select the size of the cassette for which
you want to register the basic setting:
UP-STMTR
LOW-STMTR
10) Note that basic setting 2 has been regis-
tered.
5-34
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001