Others; Copier - Canon CLC5000 Service Manual

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

CHAPTER 1 GENERAL DESCRIPTION

1.3 Others

1.3.1 Copier

Operating environment
Power supply (rated voltage ±10%)
Power consumption
Noise
Ozone
Consumables
Dimensions
Weight
1-4
Temperature: 15 to 27.5ºC
Humidity: 25% to 75%
Atm pressure: 810.6 hPa to 1013.3 hPa (0.8 to 1.0 atm)
Power supply
200V
208/240V
230V
230V
230V
230V
230V
230V
230V
3 KW or less (during copying, A4, full-color continuous)
0.62 KW (during standby; reference only)
77 dB (during copying)
71 dB (during standby)
0.02 ppm or less
(upon installation)
Paper
Keep wrapped to protect against humidity.
Toner
Avoid direct sunlight, and keep it at 40ºC or lower.
Fixing oil
Avoid direct sunlight.
See F01-103-01.
490.0 kg (body only)
3.7 kg (copyboard)
4.9 kg (editor)
28.5 kg (A4 paper deck)
39.4 kg (A3 paper deck)
COPYRIGHT © 2001 CANON INC.
Serial No.
LQZxxxxx
NSXxxxxx (UL)
PRXxxxxx (ITA)
SCZxxxxx (FRN)
TDLxxxxx (GER)
UHBxxxxx (AMS)
PRMxxxxx (general)
QEBxxxxx (UK)
PDQxxxxx (CA)
T01-103-01
2000 2000 2000 2000
ISO sound power level
(1 m from machine)
0.05 ppm
(100,000 copies or 1 yr)
CANON CLC5000 REV.0 JAN. 2001