Power Supply; Outline - Canon CLC5000 Service Manual

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

9.6 Power Supply

9.6.1 Outline

The following diagram shows how power is distributed. The buffer pass unit is supplied
with +5V and +24V power by the buffer pass power supply. +24 V is supplied by way of the
cover switch (SW1) to the loads; it will be cut off when the front cover of the buffer pass
unit is opened and, as a result, the cover switch turns off.
Leakage
breaker
Noise
filter
Buffer pass
power supply
outlet
To sorter
COPYRIGHT © 2001 CANON INC.
Cover switch (SW1)
Cover switch
REMON
J303-2
+24V
J301-1,3
Buffer pass driver PCB
F02-906-01
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
CHAPTER 2 NEW FUNCTIONS
+24VR
+24VR
+24VR
+24VR
+24VR
+24VR
+24VR
+5V
+5V
24V/5V
DC/DC converter
+5V
+5V
+5V
+5V
+5V
+5V
Reversal motor (M2)
Buffer pass motor (M1, M3)
Flapper solenoid (SL1)
Downward curl removing
solenoid 1 (SL3)
Downward curl removing
solenoid 2 (SL4)
Upward curl removing
solenoid 1 (SL5)
Upward curl removing
solenoid 2 (SL6)
Reversal timing sensor 1 (PS1)
Reversal jam sensor 2 (PS2)
Delivery paper sensor (PS3)
Upper phase sensor 1 (PS4)
Upper phase sensor 2 (PS5)
Lower phase sensor 1 (PS6)
Lower phase sensor 2 (PS7)
Inlet paper sensor (PS8)
2-227