2.10.4 Checking the Photointerrupters

The CLC1000 allows you to use a conventional meter or service mode when checking its
photointerrupters.
a. Using a Meter
1) Set the meter to the 30VDC range.
2) Connect the – probe of the meter to J101-7 (GND) of the DC control PCB.
3) Connect the + probe to the terminals (on the DC controller PCB or the deck controller
PCB) shown on the pages that follow.
4) Make checks according to the instructions given.
b. Using Service Mode
1) Start service mode.
2) Press 'DISP'.
3) Press 'SENSOR'.
4) Make checks as indicated.
DISP
COUNTER
ADJUST
FUNC
OPTION
TEST
COPYRIGHT © 2001 CANON INC.
CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS