h. Removing the Developing Bias High-Voltage Assembly (HVT3)
1) Remove the rear cover (2)/(3).
2) Disconnect the four connectors [1], and
remove the four screws [2]; then, detach
the power supply cooling fan unit [3].
3) Disconnect the conductor [4] and re-
move the three screws [5] from the
pickup drive PCB; then, detach the
pickup driver unit [6].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
CHAPTER 2 NEW FUNCTIONS
[2]
[2]
F02-706-33
[4]
[5]
[4]
[4]
F02-706-34
[1]
[2]
[3]
[4]
[6]
[4]
[5]
2-175
[2]