CHAPTER 2 NEW FUNCTIONS

9.7.2 Feeding System

a. Removing the Upper Curl removing Roller
1) Open the front cover.
2) Remove the two screws [1], and detach
the retainer handle [2] together with the
handle support base [3].
When mounting the retaining
handle, be sure to fit the pin [4]
on the slide shaft with the cut-
off in the handle.
2-230
COPYRIGHT © 2001 CANON INC.
[3]
[1]
F02-907-02
F02-907-03
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
[2]