c. Mounting the Process Unit
1) Remove all developing assemblies, and attach the drum protection sheet [1] to each pho-
tosensitive drum.
Photosensitive
drum for M/Y/Bk
Check to make sure that
the edge of the white paper
is found as shown by the
naked eye.
Do not touch the area where contact will be made with the drum.
Before putting it to use, be sure to dry wipe it with lint-free paper.
COPYRIGHT © 2001 CANON INC.
[1]
Plastic sheet
F02-405-22