Canon CLC5000 Service Manual page 740

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

E061
Cause
• Laser unit (faulty)
• Laser shutter (faulty)
• Photosensitive drum (faulty)
• Scanner (faulty)
• Video controller PCB (faulty)
• Laser intensity (adjustment faulty)
Description
xx20 The computation value of V00 is the upper limit value (800 V) or
xx21 The computation value (750 V) of Vdc is the upper limit value
xx22 The computation value of Vg is the upper limit value (950 V) or
xx23 The computation value of V00 is the upper limit value (950 V) or
Cause
• Potential measurement unit (faulty)
• HVDC (faulty)
• Laser unit (faulty)
• Video controller PCB (faulty)
• Laser intensity (adjustment fault)
Description
xx24 The computation value of Vdc is the lower limit value (200 V) or
xx25 The computation value of V00 is the lower limit value (325 V) or
xx26 The computation value of Vg is the lower limit value (250 V) or
xx27 The computation value of VFF is the lower limit value (700 V) or
xx28 The computation value of VFF is the lower limit value (0 V) or
Cause
• Video controller PCB (faulty)
• Laser unit (faulty)
• Laser intensity (adjustment fault)
• Photosensitive drum (faulty)
• Scanner (faulty)
• Potential measurement unit (faulty)
• HVDC (faulty)
COPYRIGHT © 2001 CANON INC.
higher.
(750 V) or higher.
higher.
higher.
lower.
lower.
lower.
lower.
lower.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001