Canon CLC5000 Service Manual page 312

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

Step
13
Turn the cam by hand so that the belt
unit is in UP position.
14
Disconnect the two connectors, and
loosen the screw ; then, shift the locking
plate to the left.
15
Push the cleaning blade to release the
pressure, and lift the middle of the inlet
guide.
When lifting the inlet guide,
be sure to support at its middle
to avoid deforming the guide.
COPYRIGHT © 2001 CANON INC.
Work
2000 2000 2000 2000
CHAPTER 3 INSTALLATION
Remarks
Belt unit
F03-302-11
Screw
F03-302-12
F03-302-13
CANON CLC5000 REV.0 JAN. 2001
Cam
connector
Locking plate
Inlet guide
Cleaner
blade
3-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fy8-13gz-000

Table of Contents