4) Set the laser power checker switch to '2'.
5) Insert the laser power checker with its light-receiving face oriented as indicated in F05-
208-03.
Light-
receiving
face
Light-
receiving
face
6) Insert the lead wire of the laser power checker into the Digital Multimeter, and set it to
the 200 mV range.
7) Start service mode, and execute 'POWER' and '1/2 POWER' of '6 LASER' under
'FUNC'.
8) Check to make sure that the reading of the Digital Multimeter is 'POWER: 44.8 ±0.4
mV, 1/2 POWER: 20.0 ±0.2 mV'. If the readings are not as specified, make the follow-
ing adjustments:
COPYRIGHT © 2001 CANON INC.
CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
Laser power checker
Bk laser unit
F05-208-03
2000 2000 2000 2000
C laser unit
CANON CLC5000 REV.0 JAN. 2001