<HV-SP (separation high-voltage output fine-adjustment by
condition)>
DISP
COUNTER
ADJUST
FUNC
OPTION
TEST
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
SP-OFST
Adjusts the transfer high-voltage output.
Settings range –5 ~ +5 (Standard: 0)
Unit: 25 µA
ZONE-A/B/C
Indicates the machine internal humidity absolute value (g) in the three
ranges of A through C.
Note 1:
The setting of this item will return to the default value when the PCB is re-
placed or the RAM is cleared, requiring input once again. Be sure to record
any new setting you have made on the service label.
COPYRIGHT © 2001 CANON INC.
<M>
<S>
HV-SP
1/4
xxx
xxx
BODY
˚C
BODY
xxx
xxx
%
BODY
xxx
xxx
g
SP-OFST
xxxx
F00-300-27
2000 2000 2000 2000
<R>
READY
ZONE A
ZONE B
580g
ZONE C
1800g
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
<P>
<F>
READY
0.0g
to
580g
see
2/4
1800g
see
3/4
to
-----g
see
4/4
to
S-65