Canon CLC5000 Service Manual page 278

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

e. Removing the Feed roller (reversal confluence)
1) Remove the rear cover.
2) Remove heater reversal inlet roller. (See
d. above.)
3) Remove the tension spring [1], and re-
move the four screws [2]; then, detach
the buffer pass motor [3] together with
its mounting base.
4) Open the front cover.
5) Pull the retaining handle to the front,
and push up the retaining unit. (See
F02-907-17.)
6) Remove the E-ring [4], washer [5], and
bearing [6] at the front.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
CHAPTER 2 NEW FUNCTIONS
[2]
[2]
F02-907-21
[4]
[5]
F02-907-22
[3]
[1]
[6]
2-239