CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
1) If you have replaced the laser unit for
C/Bk, position the analog processor
PCB as indicated in F05-208-01.
2) Turn on the power switch.
3) Open the laser power checker inlet
cover.
Y laser power
checker inlet
cover
Analog
processor
PCB
Bk laser power
checker inlet cover
5-46
Bk laser unit
F05-208-02
COPYRIGHT © 2001 CANON INC.
Analog processor PCB
Claw
Copyboard glass
F05-208-01