2.2 Original Illuminating System

2.2.1 When Replacing the Scanning Lamp, Standard White Plate, Lamp
Regulator, Reflecting Lamp Cover, Reader Controller PCB, Flash
memory on Reader Controller PCB, or Analog Processor PCB CCD
Unit
1) Execute data reading using 'CCD' un-
der 'FUNC' in service mode.

2.2.2 Routing the Scanner Cable

You must keep the mirror position-
ing tool (FY9-3040-000) near at
hand before routing the scanner
cable.
1) Remove the left cover and the hopper
left cover.
2) Remove the control panel.
3) Remove the vertical size plate and the
right glass retainer right, and remove
the copyboard glass.
4) Move the No. 2 mirror mount until the
pulley shaft [1] of the No. 2 mirror
mount is visible through the long hole
[2] in the side plate.
COPYRIGHT © 2001 CANON INC.
CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
2000 2000 2000 2000
F05-202-02 (front)
CANON CLC5000 REV.0 JAN. 2001
[1]
[2]
F05-202-01 (rear)
[1]
[2]
5-17