Canon CLC5000 Service Manual page 650

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

<HV-TR (transfer high-voltage output adjustment by condition)>
DISP
COUNTER
ADJUST
FUNC
OPTION
TEST
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
BODY %
Indicates the machine internal humidity measured by the environment sen-
sor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
TRY-OFS-Y/M/C/K
Adjusts the transfer high-voltage output.
Settings range -5 ~ +5 (standard: 0)
Unit: 1.0 µA
ZONE-A/B/C
Indicates the machine internal humidity absolute value (g) in the three
ranges of A through C.
Note 1:
The setting of this item will return to the default value when the PCB is re-
placed or the RAM is cleared, requiring input once again. Be sure to record
any new setting you have made on the service label.
COPYRIGHT © 2001 CANON INC.
<M>
<S>
HV-TR-Y
1/4
BODY
xxx
˚C
BODY
xxx
%
BODY
xxx
g
TR-OFS-Y
xxxx
F00-300-25
If you have changed the settings of 'TRY-OFS-C/M/Y/K',
check to make sure that the value of 'TR-#' for each zone is
'0'; otherwise, enter '0'.
2000 2000 2000 2000
<R>
READY
ZONE A
ZONE B
580g
ZONE C
1800g
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
<P>
<F>
READY
0.0g
to
580g
see
2/4
to
1800g
see
3/4
-----g
see
4/4
to
S-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fy8-13gz-000

Table of Contents