Extension Calls Out Format; From Extension A - Altigen AltiWare OE Version 4.6 Administration Manual

Table of Contents

Advertisement

SMDR Reporting Format

Extension Calls Out Format:

09/01 08:12P 00:00:33 109
(Start, Length)
(0, 1)
(1, 5)
(6, 1)
(7, 6)
(13, 1)
(14, 8)
(22, 1)
(23, 4)
(27, 6)
(33, 26)
(59, 2)
(61, 4)
(72, 8)
(80, 1)

From Extension A

Extension A: 100
Extension B: 111
Outside #: 3210002:
1
Dial out
2
Ext B fwd to Trk Y
3
Ext B ONA to Trk Y
16 AltiWare OE System Installation & Administration Manual
2526352
Field
space
date
space
start time
space
duration
space
calling party
space
called number
space
trunk PAD number
account code
delimiter
Calls Initiated by Extension A (Column A)
11/18 05:53P 00:00:28 100
11/18 05:55P 00:00:21 100
11/18 05:57P 00:00:17 100
0411
Format
mm/dd
hh:mmP
P = pm, A = am
hh:mm:ss
xxyy
x = board numb.
y = channel numb.
1 to 10 digits
line feed
3210002
3210002
3210002
:
12345678
Notes
0100
0001
0100