Board; Troubleshooting-Common Symptoms - Altigen AltiWare OE Version 4.6 Administration Manual

Table of Contents

Advertisement

Configuring the Triton T1/PRI Board
Pin 2=Receive Tip (INPUT)
Pin 4=Transmit Ring (OUTPUT)
Pin 5=Transmit Tip (OUTPUT)
Troubleshooting—Common Symptoms
The most common problems when installing T1 or PRI services:
1.
The service provider misconfigures your T1/PRI service or terminates
your service improperly.
2.
T1 is installed but not turned on because there is no termination device
for a period of time.
3.
T1 is turned on but channel is not in service.
AltiAdmin provides basic troubleshooting information in the T1 Span
Configuration window, described in "Triton T1 Configuration - Triton T1/
PRI Dialog Box" on page 6-34.
Several diagnostic tools are available that can help troubleshoot these
situations, such as a T1 watcher ("T-Berd") or a multimeter. For more
information, check the Communication Technology Corp. web site at
www.commtech.com.
6-44 AltiWare OE System Installation & Administration Manual