Replacing A Fixed Fan; Figure 127. Installing A Fan Into The Redundant Fan Module - Intel SR2625UR - Server System - 0 MB RAM Service Manual

Service guide
Hide thumbs Also See for SR2625UR - Server System - 0 MB RAM:
Table of Contents

Advertisement

Note: Fan locations 1, 2, 3, and 4 use 80-mm fans. Fan locations 5 and 6 use 60-mm fans.
3. With the fan oriented correctly, insert the fan into the fan module, engaging the
connector on the fan into the matching connector on the fan module (see
Figure

Replacing a Fixed Fan

Caution: The system fans are NOT hot-swappable. Before removing or replacing a fan, you must
first take the server out of service, turn off all peripheral devices connected to the system,
turn off the system by pressing the power button, and unplug the AC power cord from the
system or wall outlet.
Note: The fans that are integrated into the power supply cannot be replaced separately. If one of
the fans in the power supply fails, the power supply must be replaced.
The system fans at the front of the server system can be individually replaced if one of
them fails.
To replace a fan, follow these steps:
®
Intel
Server System SR2600UR/SR2625UR Service Guide
127).
LX

Figure 127. Installing a Fan into the Redundant Fan Module

133