Removing DIMMs

To remove a DIMM, follow these steps:
1. Remove the PCI riser assembly. For instructions, see
Assembly" on page
2. Remove the processor air duct. For instructions, see
Duct" on page 56
3. Locate the DIMM sockets (see
4. Gently spread the retaining clips at each end of the socket. The DIMM lifts from
the socket.
5. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static
package.

Installing or Replacing the Processor

Caution: Processor must be appropriate: You may damage the server board if you install a
processor that is inappropriate for your server. For a web link to the list of compatible
processor(s), see
Caution: ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to
the processor by doing the following: (1) Touch the metal chassis before touching the
processor or server board. Keep part of your body in contact with the metal chassis to
dissipate the static charge while handling the processor. (2) Avoid moving around
unnecessarily.
Caution: Protective socket cover needs to be removed for proper cooling of the processor; failure to
remove the cover could result in damage to the system.
®
Intel
Server System SR2600UR/SR2625UR Service Guide
50.
Figure
"Additional Information and Software" on page
"Removing the PCI Riser
"Removing the Processor Air
40).
4.
59