Removing the Small Air Baffle ..................................................................................... 66
Installing the Small Air Baffle .......................................................................................66
Removing and Installing the Fan Baffle ...............................................................................67
Removing the Fan Baffle ............................................................................................. 67
Installing the Fan Baffle ...............................................................................................69
Removing and Installing the Large Air Baffle .......................................................................70
Removing the Large Air Baffle .....................................................................................70
Installing the Large Air Baffle ....................................................................................... 70
Installing a SAS or SATA Hot-swap Hard Disk Drive .................................................. 71
Removing a SAS or SATA Hot-swap Hard Disk Drive ................................................74
only) .............................................................................................................................74
Installing a Hot-swap SAS/SATA Hard Disk Drive ...................................................... 75
Removing a Hot-swap SAS/SATA Hard Disk Drive .................................................... 76
SR2600UR only) .......................................................................................................... 77
Installing a Slimline Optical Drive or Internal USB Floppy ........................................... 78
Removing a Slimline Optical Drive or Internal USB Floppy .........................................80
Installing a Slimline Optical Drive ................................................................................ 82
Removing a Slimline Optical Drive ..............................................................................83
Installing a Tape Drive .........................................................................................................84
Installing the 2.5-Inch Fixed Hard Disk Drives .....................................................................90
Installing and Removing the I/O Expansion Module ............................................................ 97
Installing the I/O Expansion Module ............................................................................97
Removing the I/O Expansion Module ..........................................................................98
Installing the Intel
Removing the Intel
Replacing the Midplane Board ...........................................................................................103
Removing the Midplane Board ..................................................................................103
Installing the Midplane Board .................................................................................... 105
Replacing the Backplane ...................................................................................................108
Removing the Backplane ...........................................................................................108
Installing the Backplane .............................................................................................110
Only) ..........................................................................................................................112
Installing the RAID Activation Key and the RAID Mini-DIMM ....................................112
Removing the RAID Activation Key and the RAID Mini-DIMM ..................................113
®
Intel
Server System SR2600UR/SR2625UR Service Guide
®
Server System SR2600UR only) .........................87
®
Server System SR2600UR only) .......................95
®
Server System SR2625UR only) .......................96
®
Remote Management Module 3 ...................................99
®
RMM3 ........................................................................................... 99
®
RMM3 .......................................................................................102
®
®
®
®