Sign In
Upload
Manuals
Brands
Intel Manuals
Chassis
SR1560SF - Server System - 0 MB RAM
Intel SR1560SF - Server System - 0 MB RAM Manuals
Manuals and User Guides for Intel SR1560SF - Server System - 0 MB RAM. We have
3
Intel SR1560SF - Server System - 0 MB RAM manuals available for free PDF download: Service Manual, Hardware Installation Manual
Intel SR1560SF - Server System - 0 MB RAM Service Manual (158 pages)
Server System
Brand:
Intel
| Category:
Server
| Size: 3 MB
Table of Contents
Preface
5
About this Manual
5
Manual Organization
5
Product Contents
6
Intel ® Server System SR1560SF - Product Code SR1560SFHS Contents
7
Safety Information
9
Important Safety Instructions
9
Consignes de Sécurité
9
Wichtige Sicherheitshinweise
9
Instrucciones de Seguridad Importantes
9
Table of Contents
13
Chapter 1: Server System References
23
Table 1. Server System References
23
Chapter 2: Server System Features
25
Figure 1. Intel ® Server System SR1560SF
25
Table 2. Intel ® Server System SR1560SF Feature Summary
26
Cable Routing (Hot-Swap Drive System)
28
Figure 2. Cable Routing for Hot-Swap Drive System
28
Cable Routing (Fixed Drive System)
29
Figure 3. Cable Routing for Fixed Drive System
29
Chassis Component Identification
30
Internal Components
30
Figure 4. System Components
30
Figure 5. Server Board Connector and Component Locations
31
Configuration Jumpers
32
Figure 6. BIOS Select Jumper
32
Figure 7. Recovery Jumpers
33
Figure 8. Light Guided Diagnostic Leds
34
Figure 9. Back Panel Connectors
35
Table 3. NIC LED Descriptions
35
Figure 10. Active/Passive Backplane Components
36
Front of Server System
37
Standard Control Panel
37
Bezels
38
Figure 11. Standard Control Panel
38
Rear of Server System
39
Figure 12. Server System Back
39
RAID Support
37
Peripheral Devices
40
Hard Disk Drives
40
Figure 13. Optional Peripherals
40
Slimline Optical Drive Carrier
41
Rack-Mounted Systems
41
Chapter 3: Hardware Installations and Upgrades
43
Before You Begin
43
Tools and Supplies Needed
43
System References
43
Removing and Installing the Front Bezel
43
Removing the Front Bezel
44
Installing the Front Bezel
44
Removing and Installing the System Cover
44
Removing the System Cover
44
Figure 14. Removing the Front Bezel
44
Figure 15. Installing the Front Bezel
44
Installing the System Cover
45
Figure 16. Removing the Server System Cover
45
Figure 17. Installing the Server System Cover
45
Removing and Installing the Processor Air Duct
46
Removing the Processor Air Duct
46
Installing the Processor Air Duct
46
Figure 18. Removing the Processor Air Duct
46
Figure 19. Removing the Processor 2 Air Dam (Optional - Only if Two Processors Are Installed)
46
Installing and Removing Memory
47
Figure 20. Installing the Processor Air Duct
47
Figure 21. Installing the Initial Four Dimms
48
Figure 22. Installing the Memory
49
Installing Dimms
49
Removing Dimms
49
Figure 23. Lifting the Processor Socket Handle
50
Figure 24. Installing the Processor
50
Installing the Processor
50
Figure 25. Removing the Socket Cover
51
Installing the Heat Sink(S)
51
Removing a Processor
52
Removing and Installing the Small Air Baffle
52
Figure 26. Installing the Heat Sink (1U Passive Heat Sink Shown)
52
Figure 27. Removing the Small Air Baffle
53
Figure 28. Installing the Small Air Baffle
53
Installing the Small Air Baffle
53
Removing the Small Air Baffle
53
Installing and Removing a Hot-Swap Hard Drive
54
Installing a SAS or SATA Hot-Swap Hard Disk Drive
54
Figure 29. Removing Hot-Swap Disk Carrier from the Server System
54
Figure 30. Removing Drive Blank from Drive Carrier
54
Removing a SAS or SATA Hot-Swap Hard Disk Drive
55
Figure 31. Installing Hard Drive into Carrier
55
Figure 32. Install Drive Assembly into the Server System
55
Installing and Removing a Fixed Hard Drive
56
Installing a Fixed Hard Disk Drive
56
Figure 33. Removing the Drive Blank from the Fixed Hard Drive Carrier
56
Removing a Fixed Hard Disk Drive
57
Figure 34. Installing Fixed Hard Drive into the Carrier
57
Figure 35. Removing Fixed Hard Drive from the Server System
57
Installing or Removing a Slimline Optical Drive
58
Installing a Slimline Optical Drive
58
Figure 36. Installing an Optical Drive into the Drive Tray
58
Removing a Slimline Optical Drive
59
Figure 37. Installing an Optical Drive Assembly into the Server System
59
Figure 38. Removing the Slimline Optical Drive Assembly from the Server System
59
Filling Empty Server System Bays
60
Installing and Removing the PCI Riser Assembly
60
Removing the PCI Riser Assembly
60
Figure 39. Removing the Slimline Optical Drive from the Tray
60
Installing the PCI Riser Assembly
61
Figure 40. Removing PCI Riser Assembly from the Server System
61
Figure 41. Installing PCI Riser Assembly into the Server System
61
Installing and Removing a PCI Add-In Card
62
Installing a PCI Add-In Card
62
Removing a PCI Add-In Card
62
Figure 42. Installing a Full Height Add-In Card
62
Figure 43. Removing a Full Height Add-In Card
62
Installing and Removing the I/O Expansion Module(S)
63
Installing the I/O Expansion Module(S)
63
Removing the I/O Expansion Module(S)
63
Figure 44. Installing the I/O Expansion Module to the Server Board
63
Figure 45. Removing the I/O Expansion Module(S) from the Server Board
63
Rmm2 Nic
64
Installing the Intel ® RMM2 and Intel ® RMM2 NIC
64
Removing the Intel ® RMM2 and Intel ® RMM2 NIC
65
Installing/Replacing the Backplane Board (Hot-Swap Drive System Only)
65
Installing the Backplane Board
65
Figure 48. Installing the Backplane into the Server System
66
Figure 49. Installing the Bridge Board into the Server System
66
Removing the Backplane Board
67
Figure 50. Removing the Bridge Board from the Server System
67
Replacing the Fan Board (Fixed Drive System Only)
68
Removing the Fan Board
68
Figure 51. Removing the Backplane from the Server System
68
Figure 52. Removing the Fan Board from the Server System
68
Installing the Fan Board
69
Replacing the Server Board
69
Removing the Server Board
69
Figure 53. Installing the Fan Board into the Server System
69
Figure 54. Removing the Server Board
70
Installing the Server Board
71
Figure 55. Installing the Server Board
71
Replacing the Backup Battery
72
Replacing the Power Supply
73
Figure 56. Replacing the Backup Battery
73
Replacing the Control Panel Module (Hot-Swap Drive System)
74
Figure 57. Removing Power Supply from the Server System
74
Figure 58. Installing Power Supply into the Server System
74
Figure 59. Removing the Control Panel Module (Hot-Swap Drive System)
75
Figure 60. Installing Control Panel Module into the Server System (Hot-Swap Drive System)
75
Replacing the Control Panel Module (Fixed Drive System)
76
Figure 61. Removing the Control Panel Module (Fixed Drive System)
76
Replacing a System Fan
77
Figure 62. Installing Control Panel Module into the Server System (Fixed Drive System)
77
Figure 63. Removing a Fan from the Fan Module
78
Figure 64. Installing a Fan into the Fan Module
78
Installing and Removing the Rack Handles
79
Installing the Rack Handles
79
Removing the Rack Handles
79
Figure 65. Installing the Rack Handle
79
Figure 66. Removing the Rack Handle
79
Chapter 4: Server Utilities
81
Using the BIOS Setup Utility
81
Starting Setup
81
If You Cannot Access Setup
81
Setup Menus
81
Table 4. Setup Menu Key Use
82
Upgrading the BIOS
83
Preparing for the Upgrade
83
Upgrading the BIOS
84
Clearing the CMOS
84
Figure 67. Clear CMOS Jumper
84
Resetting the Password
85
Figure 68. Password Reset Jumper
85
Appendix A: Technical Reference
87
600W Single Power Supply Input Voltages
87
System Environmental Specifications
87
Table 5. System Environmental Specifications
87
Appendix B: Intel ® Server Issue Report Form
89
Operating System Information
90
Appendix C: LED Decoder
93
Figure 69. Diagnostic LED Placement Diagram
93
Table 6. POST Progress Code LED Example
93
Table 7. Diagnostic LED POST Code Decoder
94
Appendix D: Getting Help
99
World Wide Web
99
Telephone
99
Latin America
100
Appendix E: Regulatory and Compliance Information
103
Product Regulatory Compliance
103
Product Safety Compliance
103
Product Regulatory Compliance References
104
Table 8. Product Regulatory Compliance Markings
104
Electromagnetic Compatibility Notices
107
FCC Verification Statement (USA)
107
Industry Canada (ICES-003)
108
Europe (CE Declaration of Conformity)
108
VCCI (Japan)
108
BSMI (Taiwan)
108
Korean Compliance (RRL)
109
CNCA (CCC-China)
109
Product Ecology Compliance
109
Table 9. Product Ecology Compliance Markings
110
Table 10. Other Markings
112
Regulated Specified Components
113
End-Of-Life / Product Recycling
114
Appendix F: Warranty
115
Limited Warranty for Intel® Chassis Subassembly Products
115
Warranty Limitations and Exclusions
116
Limitations of Liability
116
How to Obtain Warranty Service
116
Telephone Support
117
Returning a Defective Product
117
Appendix G: Installation/Assembly Safety Instructions
119
English
119
Deutsch
121
Français
123
Español
125
Chinese
128
Italiano
128
Appendix H: Safety Information
131
English
131
Server Safety Information
131
Safety Warnings and Cautions
131
Intended Application Uses
132
Site Selection
132
Equipment Handling Practices
132
Power and Electrical Warnings
133
System Access Warnings
134
Rack Mount Warnings
134
Electrostatic Discharge (ESD)
135
Other Hazards
135
Deutsch
136
Sicherheitshinweise für den Server
136
Sicherheitshinweise und Vorsichtsmaßnahmen
136
Zielbenutzer der Anwendung
137
Standortauswahl
137
Handhabung von Geräten
137
Warnungen zu Netzspannung und Elektrizität
138
Warnhinweise für den Systemzugang
139
Warnhinweise für Racks
139
Elektrostatische Entladungen (ESD)
140
Andere Gefahren
140
Français
141
Consignes de Securite Sur Le Serveur
141
Séurité: Avertissements Et Mises en Garde
141
Domaines D'utilisation Prévus
142
Sélection D'un Emplacement
142
Pratiques de Manipulation de L'équipement
143
Alimentation Et Avertissements en Matiére D'électricité
143
Avertissements Sur Le Cordon D'alimentation
144
Avertissements Sur L'accés Au Systéme
144
Avertissements Sur Le Montage en Rack
145
Décharges Électrostatiques (ESD)
146
Autres Risques
146
Périphériques Laser
147
Español
147
Información de Seguridad del Servidor
147
Advertencias y Precauciones sobre Seguridad
147
Aplicaciones y Usos Previstos
148
Seleccién de la Ubicación
148
Manipulacién del Equipo
149
Advertencias de Alimentacién y Eléctricas
149
Advertencias sobre el Cable de Alimentación
149
Advertencias el Acceso al Sistema
150
Advertencias sobre el Montaje en Bastidor
151
Descarga Electrostática (ESD)
152
Otros Riesgos
152
Advertisement
Intel SR1560SF - Server System - 0 MB RAM Service Manual (158 pages)
Server System
Brand:
Intel
| Category:
Server
| Size: 3 MB
Table of Contents
Preface
5
About this Manual
5
Manual Organization
5
Product Contents
6
Intel ® Server System SR1560SF - Product Code SR1560SFHS Contents
7
Safety Information
9
Important Safety Instructions
9
Consignes de Sécurité
9
Wichtige Sicherheitshinweise
9
Instrucciones de Seguridad Importantes
9
Table of Contents
13
Chapter 1: Server System References
23
Table 1. Server System References
23
Chapter 2: Server System Features
25
Figure 1. Intel ® Server System SR1560SF
25
Table 2. Intel ® Server System SR1560SF Feature Summary
26
Cable Routing (Hot-Swap Drive System)
28
Figure 2. Cable Routing for Hot-Swap Drive System
28
Cable Routing (Fixed Drive System)
29
Figure 3. Cable Routing for Fixed Drive System
29
Chassis Component Identification
30
Internal Components
30
Figure 4. System Components
30
Figure 5. Server Board Connector and Component Locations
31
Configuration Jumpers
32
Figure 6. BIOS Select Jumper
32
Figure 7. Recovery Jumpers
33
Figure 8. Light Guided Diagnostic Leds
34
Figure 9. Back Panel Connectors
35
Table 3. NIC LED Descriptions
35
Figure 10. Active/Passive Backplane Components
36
Front of Server System
37
Standard Control Panel
37
Bezels
38
Figure 11. Standard Control Panel
38
Rear of Server System
39
Figure 12. Server System Back
39
RAID Support
37
Peripheral Devices
40
Hard Disk Drives
40
Figure 13. Optional Peripherals
40
Slimline Optical Drive Carrier
41
Rack-Mounted Systems
41
Chapter 3: Hardware Installations and Upgrades
43
Before You Begin
43
Tools and Supplies Needed
43
System References
43
Removing and Installing the Front Bezel
43
Removing the Front Bezel
44
Installing the Front Bezel
44
Removing and Installing the System Cover
44
Removing the System Cover
44
Figure 14. Removing the Front Bezel
44
Figure 15. Installing the Front Bezel
44
Installing the System Cover
45
Figure 16. Removing the Server System Cover
45
Figure 17. Installing the Server System Cover
45
Removing and Installing the Processor Air Duct
46
Removing the Processor Air Duct
46
Installing the Processor Air Duct
46
Figure 18. Removing the Processor Air Duct
46
Figure 19. Removing the Processor 2 Air Dam (Optional - Only if Two Processors Are Installed)
46
Installing and Removing Memory
47
Figure 20. Installing the Processor Air Duct
47
Figure 21. Installing the Initial Four Dimms
48
Figure 22. Installing the Memory
49
Installing Dimms
49
Removing Dimms
49
Figure 23. Lifting the Processor Socket Handle
50
Figure 24. Installing the Processor
50
Installing the Processor
50
Figure 25. Removing the Socket Cover
51
Installing the Heat Sink(S)
51
Removing a Processor
52
Removing and Installing the Small Air Baffle
52
Figure 26. Installing the Heat Sink (1U Passive Heat Sink Shown)
52
Figure 27. Removing the Small Air Baffle
53
Figure 28. Installing the Small Air Baffle
53
Installing the Small Air Baffle
53
Removing the Small Air Baffle
53
Installing and Removing a Hot-Swap Hard Drive
54
Installing a SAS or SATA Hot-Swap Hard Disk Drive
54
Figure 29. Removing Hot-Swap Disk Carrier from the Server System
54
Figure 30. Removing Drive Blank from Drive Carrier
54
Removing a SAS or SATA Hot-Swap Hard Disk Drive
55
Figure 31. Installing Hard Drive into Carrier
55
Figure 32. Install Drive Assembly into the Server System
55
Installing and Removing a Fixed Hard Drive
56
Installing a Fixed Hard Disk Drive
56
Figure 33. Removing the Drive Blank from the Fixed Hard Drive Carrier
56
Removing a Fixed Hard Disk Drive
57
Figure 34. Installing Fixed Hard Drive into the Carrier
57
Figure 35. Removing Fixed Hard Drive from the Server System
57
Installing or Removing a Slimline Optical Drive
58
Installing a Slimline Optical Drive
58
Figure 36. Installing an Optical Drive into the Drive Tray
58
Removing a Slimline Optical Drive
59
Figure 37. Installing an Optical Drive Assembly into the Server System
59
Figure 38. Removing the Slimline Optical Drive Assembly from the Server System
59
Filling Empty Server System Bays
60
Installing and Removing the PCI Riser Assembly
60
Removing the PCI Riser Assembly
60
Figure 39. Removing the Slimline Optical Drive from the Tray
60
Installing the PCI Riser Assembly
61
Figure 40. Removing PCI Riser Assembly from the Server System
61
Figure 41. Installing PCI Riser Assembly into the Server System
61
Installing and Removing a PCI Add-In Card
62
Installing a PCI Add-In Card
62
Removing a PCI Add-In Card
62
Figure 42. Installing a Full Height Add-In Card
62
Figure 43. Removing a Full Height Add-In Card
62
Installing and Removing the I/O Expansion Module(S)
63
Installing the I/O Expansion Module(S)
63
Removing the I/O Expansion Module(S)
63
Figure 44. Installing the I/O Expansion Module to the Server Board
63
Figure 45. Removing the I/O Expansion Module(S) from the Server Board
63
Rmm2 Nic
64
Installing the Intel ® RMM2 and Intel ® RMM2 NIC
64
Removing the Intel ® RMM2 and Intel ® RMM2 NIC
65
Installing/Replacing the Backplane Board (Hot-Swap Drive System Only)
65
Installing the Backplane Board
65
Figure 48. Installing the Backplane into the Server System
66
Figure 49. Installing the Bridge Board into the Server System
66
Removing the Backplane Board
67
Figure 50. Removing the Bridge Board from the Server System
67
Replacing the Fan Board (Fixed Drive System Only)
68
Removing the Fan Board
68
Figure 51. Removing the Backplane from the Server System
68
Figure 52. Removing the Fan Board from the Server System
68
Installing the Fan Board
69
Replacing the Server Board
69
Removing the Server Board
69
Figure 53. Installing the Fan Board into the Server System
69
Figure 54. Removing the Server Board
70
Installing the Server Board
71
Figure 55. Installing the Server Board
71
Replacing the Backup Battery
72
Replacing the Power Supply
73
Figure 56. Replacing the Backup Battery
73
Replacing the Control Panel Module (Hot-Swap Drive System)
74
Figure 57. Removing Power Supply from the Server System
74
Figure 58. Installing Power Supply into the Server System
74
Figure 59. Removing the Control Panel Module (Hot-Swap Drive System)
75
Figure 60. Installing Control Panel Module into the Server System (Hot-Swap Drive System)
75
Replacing the Control Panel Module (Fixed Drive System)
76
Figure 61. Removing the Control Panel Module (Fixed Drive System)
76
Replacing a System Fan
77
Figure 62. Installing Control Panel Module into the Server System (Fixed Drive System)
77
Figure 63. Removing a Fan from the Fan Module
78
Figure 64. Installing a Fan into the Fan Module
78
Installing and Removing the Rack Handles
79
Installing the Rack Handles
79
Removing the Rack Handles
79
Figure 65. Installing the Rack Handle
79
Figure 66. Removing the Rack Handle
79
Chapter 4: Server Utilities
81
Using the BIOS Setup Utility
81
Starting Setup
81
If You Cannot Access Setup
81
Setup Menus
81
Table 4. Setup Menu Key Use
82
Upgrading the BIOS
83
Preparing for the Upgrade
83
Upgrading the BIOS
84
Clearing the CMOS
84
Figure 67. Clear CMOS Jumper
84
Resetting the Password
85
Figure 68. Password Reset Jumper
85
Appendix A: Technical Reference
87
600W Single Power Supply Input Voltages
87
System Environmental Specifications
87
Table 5. System Environmental Specifications
87
Appendix B: Intel ® Server Issue Report Form
89
Operating System Information
90
Appendix C: LED Decoder
93
Figure 69. Diagnostic LED Placement Diagram
93
Table 6. POST Progress Code LED Example
93
Table 7. Diagnostic LED POST Code Decoder
94
Appendix D: Getting Help
99
World Wide Web
99
Telephone
99
Latin America
100
Appendix E: Regulatory and Compliance Information
103
Product Regulatory Compliance
103
Product Safety Compliance
103
Product Regulatory Compliance References
104
Table 8. Product Regulatory Compliance Markings
104
Electromagnetic Compatibility Notices
107
FCC Verification Statement (USA)
107
Industry Canada (ICES-003)
108
Europe (CE Declaration of Conformity)
108
VCCI (Japan)
108
BSMI (Taiwan)
108
Korean Compliance (RRL)
109
Product Ecology Compliance
109
Table 9. Product Ecology Compliance Markings
110
Table 10. Other Markings
112
Regulated Specified Components
113
End-Of-Life / Product Recycling
114
Appendix F: Warranty
115
Limited Warranty for Intel® Chassis Subassembly Products
115
Warranty Limitations and Exclusions
116
Limitations of Liability
116
How to Obtain Warranty Service
116
Telephone Support
117
Returning a Defective Product
117
Appendix G: Installation/Assembly Safety Instructions
119
English
119
Deutsch
121
Français
123
Español
125
Chinese
128
Italiano
128
Appendix H: Safety Information
131
English
131
Server Safety Information
131
Safety Warnings and Cautions
131
Intended Application Uses
132
Site Selection
132
Equipment Handling Practices
132
Power and Electrical Warnings
133
System Access Warnings
134
Rack Mount Warnings
134
Electrostatic Discharge (ESD)
135
Other Hazards
135
Deutsch
136
Sicherheitshinweise für den Server
136
Sicherheitshinweise und Vorsichtsmaßnahmen
136
Zielbenutzer der Anwendung
137
Standortauswahl
137
Handhabung von Geräten
137
Warnungen zu Netzspannung und Elektrizität
138
Warnhinweise für den Systemzugang
139
Warnhinweise für Racks
139
Elektrostatische Entladungen (ESD)
140
Andere Gefahren
140
Français
141
Consignes de Securite Sur Le Serveur
141
Séurité: Avertissements Et Mises en Garde
141
Domaines D'utilisation Prévus
142
Sélection D'un Emplacement
142
Pratiques de Manipulation de L'équipement
143
Alimentation Et Avertissements en Matiére D'électricité
143
Avertissements Sur Le Cordon D'alimentation
144
Avertissements Sur L'accés Au Systéme
144
Avertissements Sur Le Montage en Rack
145
Décharges Électrostatiques (ESD)
146
Autres Risques
146
Périphériques Laser
147
Español
147
Información de Seguridad del Servidor
147
Advertencias y Precauciones sobre Seguridad
147
Aplicaciones y Usos Previstos
148
Seleccién de la Ubicación
148
Manipulacién del Equipo
149
Advertencias de Alimentacién y Eléctricas
149
Advertencias sobre el Cable de Alimentación
149
Advertencias el Acceso al Sistema
150
Advertencias sobre el Montaje en Bastidor
151
Descarga Electrostática (ESD)
152
Otros Riesgos
152
Intel SR1560SF - Server System - 0 MB RAM Hardware Installation Manual (16 pages)
Basic Rail Kit for Server Chassis
Brand:
Intel
| Category:
Chassis
| Size: 0 MB
Table of Contents
Safety Information
3
Important Safety Instructions
3
Wichtige Sicherheitshinweise
3
Consignes de Sécurité
3
Instrucciones de Seguridad Importantes
3
Table of Contents
5
Rail Kit Installation Instructions
9
Before You Begin
9
Tools and Supplies Needed
9
Kit Content List (AXXBASRAIL13)
10
Figure 1. Rail Kit Components
10
Installation Instructions
11
Remove the Inner Rail from the Rail Assembly
11
Figure 2. Removing the Inner Rail from the Rail Assembly
11
Install Outer Rail Slides to Rack Posts
12
Figure 3. Installing the Outer Rail Slides to the Rack Posts
12
Attach Inner Rails to Server Chassis Sidewalls
13
Figure 4. Attaching the Inner Rails to the Server Chassis Sidewalls
13
Install the Server Chassis into the Rack
14
Figure 5. Installing the Server Chassis into the Rack
14
Figure 6. Installing the Server Chassis into the Rack
15
Advertisement
Advertisement
Related Products
Intel SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory
Intel SR1550
Intel SR2300 - FRONT BEZEL BLK
Intel SR1425BK1 - Entry Server Platform
Intel SR1425BK1-E
Intel SR1600
Intel SR1625
Intel SR2500
Intel SR2600
Intel SR2625
Intel Categories
Motherboard
Computer Hardware
Server
Desktop
Server Board
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL