To install the heatsink, follows these steps:
1. Remove the protective film on the TIM if present.
2. Orient the heatsink over the processor as shown in
must be positioned as shown to provide correct airflow through the system.
3. Set the heatsink over the processor, lining up the four captive screws with the four
posts surrounding the processor.
4. Loosely screw in the captive screws on the heatsink corners in a diagonal manner
according to the numbers shown in
a. Starting with the screw at location 1, engage the screw threads by giving it two
b. Proceed to the screw at location 2 and engage the screw threads by giving it two
c. Engage screws at locations 3 and 4 by giving each screw two rotations and then
d. Repeat steps 4a through 4c by giving each screw two rotations each time until all
®
Intel
Server System SR2600UR/SR2625UR Service Guide
rotations in the clockwise direction and stop. (IMPORTANT: Do not fully
tighten.)
rotations and stop.
stop.
screws are lightly tightened upto a maximum of 8 inch-lbs torque.
2
TIM

Figure 47. Installing the Heatsink (Passive Heatsink Shown)

Figure
47. The heatsink fins
Figure 47
as follows:
3
1
4
AF002841