+12.0 V1
+12.0 V2
-12.0 V3
+12.0 V4
-12.0 V
Warning: Do not exceed a combined power output of 90 Watts for the +5 V and +3.3 V outputs.
Exceeding a combined 90 Watts will overload the power subsystem and may cause the
power supplies to overheat and malfunction.
System Environmental Specifications
The following table defines the system level operating and non-operating
environmental limits.
Temperature
Non-operating
Operating
Humidity
Non-operating
Shock
Operating
Packaged
Unpackaged
Vibration
Unpackaged
Acoustic noise
Electrostatic
discharge (ESD)
System Cooling
Requirement in
BTU/Hr
146
Table 6. Power Supply Output Capability
Voltage
Minimum OCP Limits
26.0 A
26.0 A
112.5% (= 18.0 A)
112.5% (= 18.0 A)
125% (= 0.625 A)
Table 7. System Environmental Specifications
-40°C to 70°C.
10°C to 35°C with the maximum rate of change not to exceed 10°C per
hour.
90% relative humidity (non-condensing) at 28°C.
2.0 g peak, 11 msec, half sine.
Non-palletized free fall in height 24 inches (> 40 lbs to < 80 lbs)
Operational after an 18" free fall.
Trapezoidal, 25 g, velocity change 136 inches/sec.
5 Hz to 500 Hz, 2.20 g RMS random.
Sound Power: 7.0 BA in an idle state at typical office ambient temperature
(23 +/- 2°C).
+/-12 KV except I/O port +/- 8 KV per Intel Environment test specification.
2550 BTU/Hr
Maximum OCP Limits
32 A max
32 A max
20 A
20 A
400% (= 2.0 A)
®
Intel
Server System SR2600UR/SR2625UR Service Guide
Need help?
Do you have a question about the SR2625UR - Server System - 0 MB RAM and is the answer not in the manual?