7. Connect the two cables to the USB and control panel connectors on the back side of
the backplane as shown (see letter "B" in
Replacing a Fan Module
See the following sections:
•
"Replacing a Redundant Fan Module" on page 128
redundant fan module
•
"Replacing a Fixed Fan Module" on page 131
module
Replacing a Redundant Fan Module
To replace a redundant fan module, follow these steps:
1. Remove the PCI riser assembly. For instructions, see
Assembly" on page
2. Remove the processor air duct. For instructions, see
Duct" on page
3. Remove the large air baffle. For instructions, see
on page
4. Remove the fan baffle. For instructions, see
5. Remove the bridge board. For instructions, see step 5 in
Board" on page
6. Disconnect the fan cables from the midplane.
126
A
Figure 121. Installing Control Panel Module into the Server System
50.
56.
70.
103.
Figure
121).
for instructions to replace a
for instructions to replace a fixed fan
"Removing the Large Air Baffle"
"Removing the Fan Baffle" on page
®
Intel
Server System SR2600UR/SR2625UR Service Guide
B a c k p l a n
e
B
AF003016
"Removing the PCI Riser
"Removing the Processor Air
"Removing the Midplane
67.