d. Close the retention mechanism on both ends to hold the bridge board in place.
8. Install the fan baffle. For instructions, see
9. Install the processor air duct. For instructions, see
Duct" on page
10. Install the PCI riser assembly. For instructions, see
Assembly" on page

Replacing the Backplane

The following sections describe how to replace the backplane.

Removing the Backplane

To remove the backplane, follow these steps:
1. Remove the midplane board. For instructions, see
on page
Note: To prevent damage to your system, you must ensure the midplane is completely removed
before attempting to remove the backplane.
2. Remove all hot-swap drive carriers, regardless of whether or not a drive is installed
in the carrier. For instructions, see
®
Intel
Server System SR2600UR/SR2625UR Service Guide

Figure 100. Installing the Bridge Board into the Server System

57.
51.
103.
C
"Installing the Fan Baffle" on page
"Installing the Processor Air
"Installing the PCI Riser
"Removing the Midplane Board"
"Removing a SAS or SATA Hot-swap Hard Disk
B
A
AF002974