CLI Commands
2–122
If the operational state is Invalid Attachment only the
following messages can be generated:
08 None
09 Unknown
10 ISL connection not allowed on this port
11 ELP rejected by the attached Switch
12 Incompatible Switch at other end of the ISL
13 External loopback adapter connected to the port
14 N_Port connection not allowed on this port
15 Non-HP switch at other end of the ISL
16 ISL connection not allowed on this port
17 ISL connection not allowed to external Fabrics
18 Port binding violation—unauthorized WWN
19 Unresponsive node connected to port
20 Incompatible security attributes
21 Fabric Binding violation
22 Authorization failure
23 Switch Binding violation
If the operational state is Inactive only the following messages
can be generated:
24 Inactive – RC 0
25 No Serial Number
26 Feature Not Enabled