HP 316095-B21 - StorageWorks Edge Switch 2/24 Reference Manual page 151

Cli reference guide for directors and edge switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Type
Attached WWN The World Wide Name of the device or Switch attached to the
Beaconing
Reason
CLI reference guide for directors and edge switches
The operational port type.
If the configured port type is F_Port or E_Port, this value will
match the configured type.
If the configured type is G_Port, this value can be E_Port,
F_Port, or G_Port, depending on what is connected to the
port.
On the Edge Switch 2/24, if the configured port type is
Fx_Port, the operational port type can include FL_Port in
addition to the values noted above for F_Port. If the
configured port type is Gx_Port, then the operational port type
can include FL_Port in addition to the values noted above for
G_Port.
port, if one is attached.
The beaconing state for the port (true or false).
An optional message number that indicates if the port has a
segmented ISL or if a port binding violation has occurred, or
if the part is inactive.
The message description for this message number is provided
at the bottom of the table.
If the operational state is Segmented E_Port, only the
following messages can be generated:
00 Segment Not Defined
01 Incompatible Operating Parameters
02 Duplicate Domain ID(s)
03 Incompatible Zoning Configurations
04 Build Fabric Protocol Error
05 No Principal Switch
06 No Response from Attached Switch
07 ELP Retransmission Failure Timeout