Config.switch.speed - HP 316095-B21 - StorageWorks Edge Switch 2/24 Reference Manual

Cli reference guide for directors and edge switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

config.switch.speed

Syntax
speed switchSpeed
Purpose
This command sets the speed for the Switch.
NOTE: This command is only applicable for the Director 2/64. Edge Switches and the Director
2/140 cannot change speed.
Description
The Switch must be set offline before this command is entered.
A Switch can be configured to operate at 1.0625 Gbps or 2.125 Gbps.
If the Switch has fibre port module (FPM) cards, configuring the Switch speed to
2.125 Gbps makes all the ports on the FPM cards inactive, and their operational state
will be set to inactive. FPM ports do not support 2.125 Gbps and, therefore, will
remain inactive after the Switch is returned to the online state.
Parameters
This command has one required parameter:
switchSpeed
Command Examples
Root> config switch speed 2g
CLI reference guide for directors and edge switches
Specifies the speed of the Switch.
Valid values are 1g (for 1.0625 Gbps) or 2g
(for 2.125 Gbps).
CLI Commands
2–55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 2/24 - edge switch

Table of Contents