Example
The following example displays RMON 1 alarms.
Console> show rmon alarm 1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field
Description
Alarm
Alarm index.
OID
Monitored variable OID.
Last Sample Value
The statistic value during the last sampling period. For example, if the sample
type is delta, this value is the difference between the samples at the beginning
and end of the period. If the sample type is absolute, this value is the sampled
value at the end of the period.
Interval
The interval in seconds over which the data is sampled and compared with the
rising and falling thresholds.
Sample Type
The method of sampling the variable and calculating the value compared
against the thresholds. If the value is absolute, the value of the variable is
compared directly with the thresholds at the end of the sampling interval. If
the value is delta, the value of the variable at the last sample is subtracted from
the current value, and the difference compared with the thresholds.