Stack Reload; Stack Master - Dell PowerConnect 3424 Cli Reference Manual

Command line interface (cli) guide (.htm)
Hide thumbs Also See for PowerConnect 3424:
Table of Contents

Advertisement

User Guidelines
The following algorithm is used to select a unit as the master:
If only one master-enabled unit is in the stack (1 or 2), it becomes the master.
If a unit configured as a forced master, it becomes the master.
If a forced master unit is removed from a stack and placed in a different stack with another
forced master unit, both are considered to be forced, and the election criteria continue as
follows:
The unit with the longer up-time is elected master. Units are considered to have the same
up-time if they were powered up within ten minutes of each other.
If both forced master units have the same up-time, Unit 1 is elected.
Example
The following example selects Unit 2 as the stack master.
Console(config)# stack master unit 2

stack reload

The stack reload Privileged EXEC mode command reloads stack members.
Syntax
stack reload [unit unit]
unit— Number of the unit to be reloaded (Range: 1-6)
Default Configuration
All units are reloaded.
Command Modes
Privileged EXEC mode
User Guidelines
If no unit is specified, all units are reloaded.
Example
The following example reloads Unit 2 of the stack.
Console(config)# stack reload unit 2