Status
Classification
Overload Counter
Short Counter
Denied Counter
Absent Counter
Invalid Signature Counter
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 3 / 0 6 – F O R P R O O F O N LY
Describes the inline power operational status of the port. Can be: On,
Off, Test-Fail, Testing, Searching or Fault.
The power consumption range of the powered device. Can be: 0.44 –
12.95, 0.44 – 3.84, 3.84 – 6.49 or 6.49 – 12.95.
Counts the number of overload conditions that has been detected.
Counts the number of short conditions that has been detected.
Counts the number of times power has been denied.
Counts the number of times power has been removed because
powered device dropout was detected.
Counts the number of times an invalid signature of a powered device
was detected.
Power over Ethernet Commands
249